adam X and
adam X pro

A digital world for jet X.

Watch video

Jetzt anfragen

A digital unit with special capabilities.
Perfect for you.

The jet X is the most advanced paint spray gun from SATA. With its innovative nozzle concept, it achieves a new outstanding surface quality for basecoats and clearcoats. It helps you achieve better finishes more easily.

The digital units of the adam X series allow you to standardise and reproduce these results at a high level.

With their diverse functions, they support you in making processes transparent and avoiding errors.

The statistics

The adam X pro keeps precise records of operating hours, painting time and the number of trigger pulls, i.e. how often the trigger was actuated.

The digital dashboard

The best database only makes sense if it is also analysed. To make this easier, the adam X pro can be connected to a personal dashboard on a PC or smartphone. This is a digital control centre in which the most important parameters of the painting process can be stored and analysed. The data is transmitted via a QR code that is shown on the display of the adam X pro.

Get to know the adam X and
adam X pro!

The adam X pro offers an unprecedented range of digital functions. This helps the professional in the paint booth analyse and control the painting process - with an unprecedented level of information and accuracy.

Highlights
Watch video

Dynamic inlet pressure

Display input flow pressure digitally

The ambient temperature

Precise temperature display of the paint booth

Operating time

Hours of use of the spray gun at a glance

The functions of the adam X pro

The menu structure is orientated towards the needs of professionals who work with the jet X on a daily basis. It is divided into two levels: the first level shows the main screen - it is always the first screen to appear after activating the adam X pro. Also on the main level: the statistics and the QR generator for transmitting data to the digital dashboard. The settings are found on the second level.

The main screen shows the most important parameters in a clearly organised display:

  • The current actual pressure
  • The previously set target pressure
  • Deviations between actual and target pressure in a graphical visualisation
  • An alarm symbol if the actual and target pressure differ by more than 0.2 bar (3 psi)
  • The dynamic pressure that was applied when the trigger was last actuated
  • Also: The ambient temperature and battery status

During painting, the display changes to a simplified, clearer display.

Target dynamic pressure 
What specifications does the paint manufacturer provide? What are your personal preferences? The target value for the dynamic inlet pressure is set here. This value is also displayed on the main screen, shown in comparison with the actual pressure in a graphical visualisation. Deviations of more than 0.2 bar trigger an optical alarm. 

Pressure and temperature units 
The pressure and ambient temperature displays can be easily switched: from bar to psi and from °C to °F. 

Multi-gun mode 
The adam X pro can be used with two paint spray guns. When multi-gun mode is activated, a menu appears when the compressed air hose is connected in which the paint spray gun currently in use can be selected. 

Other settings
Other functions can also be found at the settings level: calibration of normal pressure, information on hardware and software versions and resetting the statistics.

Worthwhile in every respect. Especially for loyal customers.

The adam X pro rewards your loyalty! If you take part in the SATA Loyalty Program coins & more, you can collect SATA coins with the new adam X pro and redeem them for attractive rewards in the Loyalty Shop.

Take part and benefit!

Learn More

adam X pro

A digital world for the jet X.

The most digital SATA of all time

adam X pro
adam X

Jetzt anfragen

Mounting on the QAC without docking station
Inlet pressure display
Conversion bar/psi
Target pressure input
Alarm function for when system exceeds or falls below the target pressure
Operating time indicator
Ambient temperature indicator
Conversion °C/°F
Battery status indicator
Double-tap operation
Tilt operation
Data on operating hours, painting time and number of trigger pulls
Transfer of important parameters to the digital dashboard
Mounting on the QAC without docking station
Inlet pressure display
Conversion bar/psi
Target pressure input
Alarm function for when system exceeds or falls below the target pressure
Operating time indicator
Ambient temperature indicator
Conversion °C/°F
Battery status indicator
Double-tap operation
Tilt operation
Data on operating hours, painting time and number of trigger pulls
Transfer of important parameters to the digital dashboard
Mounting on the QAC without docking station
Inlet pressure display
Conversion bar/psi
Target pressure input
Alarm function for when system exceeds or falls below the target pressure
Operating time indicator
Ambient temperature indicator
Conversion °C/°F
Battery status indicator
Double-tap operation
Tilt operation
Data on operating hours, painting time and number of trigger pulls
Transfer of important parameters to the digital dashboard

Jetzt anfragen